Designed for hearing aid loop calibration
Overview

Audio signal generator that can be used with the Loop-FSM to calibrate audio frequency induction loop
(AFIL) systems. This device is designed and manufactured by Magnii
Technologies for Contacta, Inc.
- Simple 1-Button Operation
- Balanced XLR Output Jack
- Outputs Sine Waves at 11 different frequencies
- Outputs Pink Noise in two different bandwidths
- Calibrate loop systems to meet IEC/EN 60118-4 standards
- Designed for use with the Loop-FSM
Contact Contacta, Inc. for purchase information.
Specifications
Specifications

- Sine Wave Frequencies:
- 80 Hz
- 100 Hz
- 125 Hz
- 250 Hz
- 500 Hz
- 1000 Hz
- 2000 Hz
- 4000 Hz
- 5000 Hz
- 6300 Hz
- 8000 Hz
- Pink Noise Bands:
- 50 Hz to 5 KHz
- 50 Hz to 15 KHz
- Sine Wave Output Level: -10 dBV
- Sine Wave Quality: <2% THD to 20 KHz
- Pink Noise Quality: ±½ dB deviation from 1/f from 100 to 5000 Hz
- Output: 600 Ohms Impedance Balanced XLR
- Auto Power-Off after 30 minutes of inactivity
- Designed to confirm loop systems meet IEC/EN 60118-4 standards
- Runs on one 9V Alkaline battery (included), lasts ~40 hours
- Unit Dimensions: 4.4" x 2.6" x 1.1"
- 1 Year Warranty
- Made in the USA